Made to the standard your consultant names — IEC/EN 60598-1 + part 2, IEC 60529, IEC 62262 — manufactured in mainland China, contracted through Hong Kong, delivered to Jebel Ali / Khalifa Port.
Typical clients: developers, hotel groups, landscape contractors and government projects in Dubai, Abu Dhabi and Sharjah. Failure on this scope is usually no product conformity registration in the destination market at customs — which is what our submittal pack proves first.
YY DESIGN is a supplier and manufacturer of landscape lighting, not a Dubai-registered contractor: we fabricate in our own plants in Foshan and Ningbo, contract through our Hong Kong entity, and supply to your main contractor or installer. Price is returned as a factory unit rate plus freight to Jebel Ali / Khalifa Port, so a landscape lighting package for a the UAE project can be compared line by line against a local trader's quote instead of a lump sum. We quote projects in Dubai, Abu Dhabi and Sharjah and hold the test reports and mill certificates that a Dubai Municipality (Building Permit & Completion) submission asks for. Lead time, pricing and project terms are confirmed per project against the drawing and the standard your consultant named.
Scopes we fabricate under this line: bollard light, pole-top luminaire, step light, wall washer, in-ground uplight, festoon and catenary — each with its own fixing detail and test basis, so the submittal is prepared per scope rather than per catalogue page.
| Standard | Scope |
|---|---|
| IEC/EN 60598-1 + part 2 | |
| IEC 60529 | IP65/IP66/IP68 |
| IEC 62262 | IK rating |
| SASO IECEE / ECAS / KUCAS as applicable |
Reports are issued by accredited laboratories in the client's or consultant's name, so they can go straight into a Dubai Municipality permits and Estidama / Al Sa'fat submissions package without a re-test request.
lighting layout, mounting detail and IP/IK requirement. Send the city, the standard the consultant named, and the date the submittal is due — one page comes back with the comparison.
Yes. We design and prefabricate in mainland China, contract through our Hong Kong entity, and ship to Jebel Ali / Khalifa Port. Most projects are installed by the client's contractor; we supply setting-out drawings, anchor details and a supervisor's checklist.
Primary tests: IEC/EN 60598-1 + part 2, IEC 60529, IEC 62262, SASO IECEE / ECAS / KUCAS as applicable. Local gate: Dubai Municipality permits and Estidama / Al Sa'fat submissions. Reports are issued in the client's or consultant's name.
Production, freight and sample dispatch timings are confirmed per project in the written agreement; sample and test report sets can be prioritised where the submittal is on the critical path.
lighting layout, mounting detail and IP/IK requirement — plus the city and the standard the consultant named. A one-page comparison is prepared after review.
IP66 is ingress protection under IEC 60529: the first 6 means dust-tight, the second 6 means protection against powerful water jets. IK10 is impact resistance under IEC 62262: 20 joules, roughly a 5 kg mass dropped from 40 cm. For landscape lighting in public areas both matter — IP against irrigation and cleaning, IK against maintenance equipment and vandalism. A luminaire can be IP66 and still fail in a year if the cable gland is the wrong size, so the gland and the breather are part of the specification.
EN 60598-1 is the general safety standard for luminaires, and EN 60598-2-3 is the part for road and street lighting. Together they cover thermal limits, wiring, creepage and clearance, mechanical strength, and the marking of the ingress protection actually achieved. The practical point for a project is that the CE marking and the test report must describe the same configuration — a report on a 3000K version does not cover a 4000K version with a different driver.
There is no single legal figure for amenity landscape lighting, which is why it is usually set by the landscape architect's specification or the authority's guidance. As a working range: pedestrian paths 10–20 lux, planting and feature trees 50–150 lux at the canopy, facades 100–200 lux, and steps or level changes noticeably brighter than their surroundings so the edge reads. Design to the task, then set the bollard spacing from the mounting height — a common rule for a 900 mm bollard is a spacing of roughly 3 to 4 times its height, tighter on steps and level changes — then check vertical illuminance on the walking surface — horizontal lux alone hides a dark step.
The usual requirements are: no upward light above the horizontal (full cut-off optics), a correlated colour temperature of 3000K or lower, and shielding so the source is not visible from a distance. The reason it is now specified on Gulf projects is ecological — coastal and desert sites sit on migration routes, and blue-rich light at 4000K and above disturbs both birds and insects. It is also cheaper to run, because the light goes where it is needed instead of into the sky.
Send the city, the scope and the date the submittal is due — Evan replies personally after reviewing your enquiry.
Prefer to ask first? Ask the AI assistant — answers in seconds →
Generated live from configuration on 2026-11-05 (content reviewed 2026-11-04) — approval authorities, codes and test basis update automatically when our standards file changes. © YY Design Group (HK) Co. Ltd